| Availability: | |
|---|---|
| Quantity: | |
MT008
Mantern
Engineered for uncompromising safety in volatile industrial environments, this oxygen gas detector transmitter combines precise electrochemical analysis with rugged physical construction. Every unit is designed to provide facility managers and safety engineers with immediate, actionable atmospheric data, ensuring personnel safety in confined spaces and critical operational zones. The robust build quality is immediately apparent in its weight and finish, reflecting a design philosophy centered on long-term reliability.
Configurable for O2 detection ranges of 0-25%vol or 0-30%vol, ensuring highly accurate atmospheric evaluation and rapid response to oxygen depletion or enrichment in confined spaces.
The physical installation utilizes a specialized triangle hole design, offering a secure, tactile mounting process. This mechanical configuration provides exceptional stability against severe industrial vibrations, ensuring the heavy-duty enclosure remains firmly anchored to structural supports.
Equipped with imported electrochemical sensors, the unit delivers exceptional sensitivity and reliable continuous monitoring. It maintains low baseline drift even during prolonged exposure to complex chemical environments, achieving a rapid response time of ≤60 seconds.
The gas detector features a heavily sealed waterproof and dustproof design side. It is engineered to perform flawlessly within a demanding working humidity range of 15-95% (RH), safeguarding the internal circuitry from moisture ingress and particulate damage.
Supports standard 2 or 3 wires configurations, outputting a reliable 4-20mA standard signal that interfaces directly with existing PLC and DCS control architectures for centralized facility management without compatibility issues.
Designed to continuously measure the gas concentration in the air. Operators can manage settings via an infrared remote control, allowing for immediate calibration adjustments and alarm configuration without needing to open the explosion-proof housing in hazardous zones.
While optimized for oxygen, this model also can detect LEL/CO/ H2S/ H2/ SO2/ NH3/ NO/ NO2/ CL2/ O3/ O2/ CO2/ PH3/ HCL/ HCHO/ C6H6, etc. according to your need, providing a unified hardware standard across diverse facility requirements.
Before deployment, every transmitter undergoes a rigorous standardized quality control process, including strict gas calibration testing to ensure absolute compliance with safety mandates. Our manufacturing facility leverages years of export experience to deliver instruments that minimize operational risk and maintenance overhead. The precise specifications below reflect the instrument's capability to perform in extreme conditions.
Sensor type: Electrochemical O2 sensor
Gas sampling: Natural diffusion
Power supply: DC24V±25%
Power consumption: ≤3W
Working method: Continuous monitoring
Error rate: ≤±5%F.S.
Indication method: 4-digit LED light
Condition display: 3 LED lights indicate fault alarm, L-alarm level alarm and H-alarm level
Operation: Infrared remote control
Response time: ≤30s (LEL) / ≤60s (toxic gas)
Working temperature: -40~70 Selsuis degree (LEL) / -20~50 Degree (toxic) Working humidity: <93%RH
Explosion-proof: Ex dIICT6
Protection: IP55
Pressure Limit: 86-106kPa
Signal output: 4~20mA
Install screw thread: G3/4"
Cable dimension: ≥1.5mm2×3
Transmit distance: ≤1000M
The following matrix details the specific detection ranges, resolutions, and dual-tier alarm thresholds (L-alarm and H-alarm) for various target gases. This precise tiering allows safety protocols to initiate automated ventilation or evacuation procedures well before hazardous concentrations become critical, providing a crucial buffer for personnel security.
Gas | Range | Resolution | L-alarm | H-alarm |
LEL | 0-100%LEL | 1%LEL | 20%LEL | 50%LEL |
LEL Vapor | 0-100%LEL | 1%LEL | 20%LEL | 50%LEL |
CO | 0-1000PPM | 1PPM | 35PPM | 200PPM |
H2S | 0-100PPM | 1PPM | 10PPM | 15PPM |
NH3 | 0-100PPM | 1PPM | 25PPM | 50PPM |
CL2 | 0-20PPM | 0.1PPM | 5PPM | 10PPM |
O2 | 0-30%VOL | 0.1%VOL | 19.5%VOL | 23.5%VOL |
SO2 | 0-500PPM | 1PPM | 10PPM | 50PPM |
CO2 | 0-6000PPM | 1PPM | 1500PPM | 2000PPM |
Securing hazardous work zones requires more than just accurate sensors; it demands a comprehensive approach to environmental safety. This oxygen gas detector transmitter is heavily deployed across demanding sectors, including chemical processing plants, metallurgical refineries, underground utility galleries, and specialized medical facilities. In these environments, the tactile, heavy cast-aluminum housing provides immediate physical reassurance of its durability. The Ex dIICT6 explosion-proof rating ensures the enclosure safely contains any internal ignition, preventing it from interacting with external volatile atmospheres, while the IP55 protection rating shields against aggressive dust and water jets common in industrial washdowns.
Beyond the physical hardware, procurement teams benefit from our extensive technical support infrastructure built on years of specialized manufacturing experience. We provide detailed CAD drawings for seamless architectural integration, comprehensive technical manuals, and direct remote installation guidance to ensure correct deployment. Furthermore, our dedicated service teams offer scheduled gas calibration protocols, ensuring the imported electrochemical sensors maintain their strict ≤±5%F.S. error rate over years of continuous operation. This end-to-end support significantly reduces the total cost of ownership, minimizes production downtime, and mitigates trial-and-error risks during critical facility upgrades.
Mantern Industrial Co., Ltd. is engaged in international business since 2012. Our aim is to provide good products with competitive price for our clients.